Fluorotherm Sanitary Shell and Tube Heat Exchangers

Sanitary Shell and Tube Heat Exchanger sanitary shell and tube heat exchangers, shell and tube heat exchangers, shell and tube heat exchanger, tube and shell exchanger, sanitary shell & tube heat exchangers

Click here for the data sheet to provide us with your operating data. Please fill out this data sheet with the information available and e-mail or fax back to us. We will respond promptly for standard product inquiries.

New - Larger sized Fluorotherm Shell and Tube Heat Exchanger available: Best Tube and Shell Exchanger


Fluorotherm is now able to offer a fluoropolymer sanitary shell and tube heat exchanger with larger areas than before. The maximum area now offered is considerably larger than the earlier limit; from 15 sq.ft to 90 sq.ft. This capability increase broadens the range of applications for our sanitary shell and tube heat exchangers from laboratory and sampling use to industrial cooling and heating applications. The unique feature of Fluorotherm designs  is that they can be disassembled, inspected, cleaned, and if necessary, repaired. Replacement of fluoropolymer tube in this non-welded construction is also possible.

Fluorotherm's sanitary shell and tube heat exchangers are designed for applications where chemical inertness to aggressive fluids is critical. The major applications for these units are in the semiconductor and ultrapure, environmental, laboratory and products finishing industries. These units have been designed with efficient heat transfer as the primary purpose, offering a cross flow heat exchanger with system fluid through shells

click to enlarge

sanitary shell and tube heat exchangers, shell and tube heat exchangers, shell and tube heat exchanger, tube and shell exchanger, sanitary shell & tube heat exchangers

sanitary shell and tube heat exchangers, shell and tube heat exchangers, shell and tube heat exchanger, tube and shell exchanger, sanitary shell & tube heat exchangers sanitary shell and tube heat exchangers, shell and tube heat exchangers, shell and tube heat exchanger, tube and shell exchanger, sanitary shell & tube heat exchangers

Tubing Coil housed in CPVC Shell

Sanitary Shell & Tube Heat Exchanger For Ultra-Pure Environment Heat Transfer with PTFE, FEP or PFA tubing coil housed in CPVC shell.

 

Shell and Tube Heat Exchanger Features

The tube side fluid flows through an ultrapure, chemically inert fluoropolymer pathway. The unit can be operated in true counterflow or in parallel flow mode. The unidirectional shell and tube side flows allow for complete purging of the unit after a batch operation is completed. Also, since there is no flow reversal, the formation of stagnant pockets is eliminated during continuous or batch operation.

Materials Available for Shell and Tube Heat Exchangers

Standard shell side materials available are PVC and CPVC. Tubing is available in PTFE, FEP, and PFA Selection of tubing type is based on, among other factors, the maximum internal pressure and the expected pressure drop* during operation. Tube side fittings are available either in PFA or PVDF. In order to help you select materials, we have included the "Pressure Drop" and the "Maximum Operating Limits" for your reference.
* Liquid flows through the unit determine the pressure drop for a given tubing type.

Notes:
a. Shell Side Materials: PVC (P), CPVC (C) Operating temperatures above 140°F for PVC and 200°F for CPVC are not recommended.
b. Tubing Materials: PTFE (T), FEP (F), PFA (P), PVDF (K)
c. Fitting Materials: PTFE (T), PFA (P), PVDF (K)
d. Heat Transfer Area: Ranges from less than 1.0 to 55.0 sq.ft
e. Tubing Type (Code): 1, 2 or 3.
Tubing type corresponds to size

For example, a 4 sq.ft unit with CPVC shell, FEP type1 tubing, and PFA tubeside fittings is described by Model CFP-641.

Key Benefits

  1. Ultimate in ultra-purity and chemical inertness
  2. Unidirectional shell and tube side flows allow for complete purging
  3. of the unit - stagnant pockets are eliminated during continuous or batch operation.
  4. Unit can be operated in true counterflow or in parallel flow mode.

New Developments

Click here for updates on our products.

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send quote - price and delivery  (Please complete the data sheet).

Need is urgent    Have a salesperson contact me    
Send product literature